"Our job is helping you do your job"
800.544.2843Email 
  • 100 Series Pressure Transmitters pic

    • Highly repeatable, shock resistant transmitters with excellent long-term stability
    • Standard ranges from vacuum to 15,000 psi; standard absolute ranges from 15 psia to 300 psia
    • Accuracy up to ±0.25% full scale (BFSL)
    • Compact size, affordable price
    • Advanced diffused semi-conductor and sputtered thin film sensor for maximum stability
    • Welded stainless steel pressure chamber
    • High alternating load resistance
    • High overpressure protection
    • Compatible with NOSHOK Smart System Indicators
    • CE compliant to suppress RFI, EMI and ESD, combined with reverse polarity and over-voltage protection to ensure reliable performance in the most demanding applications
    • Final calibration tests prior to shipment ensures 100% "out of the box" reliability
    psig = Gauge Pressure
    psia = Absolute Pressure 



    Standard Unit Includes:

    • ±0.5% Full Scale Accuracy (BFSL)
    • ¼” NPT Male Process Connection
    • Mini-Hirschmann electrical connection (with mating connector) (DIN EN 175301-803 Form C)

    NOTE: Customer must select a desired accuracy (BFSL), process connection, and electrical connection at checkout.  Other options i.e. orifice threading and calibration certificates are also available at checkout.

    *Note: For Bendix Mate cable lengths over 36 inches, please call for a quote; cable lengths over 36 inches are priced at $3.03/ft.

  • 200 Series Transducers pic

    • Highly repeatable, shock resistant transducers with excellent long-term stability
    • Standard ranges from vacuum to 15,000 psi; Standard Absolute ranges from 15 psia to 300 psia
    • Accuracy up to ±0.25% Full Scale (BFSL)
    • Compact size, affordable price
    • Advanced diffused semi-conductor and sputtered thin film sensor for maximum stability
    • Welded stainless steel pressure chamber
    • High alternating load resistance
    • High overpressure protection
    • Compatible with NOSHOK Smart System Indicators
    • CE compliant to suppress RFI, EMI and ESD, combined with reverse polarity and over-voltage protection to ensure reliable performance in the most demanding applications
    • Final calibration tests prior to shipment ensures 100% "out of the box" reliability

    psig = Gauge Pressure
    psia = Absolute Pressure


    Standard Unit Includes:

    • ±0.5% Full Scale Accuracy (BFSL)
    • ¼” NPT Male Process Connection
    • Mini-Hirschmann electrical connection (with mating connector) (DIN EN 175301-803 Form C)


    NOTE: Customer must select a desired accuracy (BFSL), output signal, process connection, and electrical connection at checkout.  Other options i.e. orifice threading and calibration certificates are also available at checkout.

    *Note: For Bendix Mate cable lengths over 36 inches, please call for a quote; cable lengths over 36 inches are priced at $3.03/ft.

  • 615-616 Series Transducers pic

    • Designed for heavy duty applications requiring high accuracy and durability
    • Extreme high pressure ranges from vacuum to 145,000 psi; Absolute ranges from 15 psia to 300 psia
    • Span and zero adjustments
    • Advanced diffused semi-conductor and sputtered thin film sensor for maximum stability
    • Excellent accuracy, shock resistance, and long term reliability
    • Rugged corrosion-resistant stainless steel construction
    • Available in a wide variety of electrical and process configurations
    • Compatible with NOSHOK 1900C and 2000 Series Smart System Indicators
    • Also available with our 1800 Series Attachable Loop Indicator
    • CE compliant to suppress RFI, EMI and ESD
    • Final calibration tests prior to shipment ensures 100% "out of the box" reliability

    psig = Gauge Pressure
    psia = Absolute Pressure


    Standard Unit Includes:

    • ±0.25% Full Scale Accuracy (BFSL)
    • 1/2” NPT Male Process Connection
    • Hirschmann electrical connection
    NOTE: Customer must select a desired accuracy (BFSL), output signal, process connection, and electrical connection at checkout.  Other options i.e. orifice threading and calibration certificates are also available at checkout.

    *Note: For Bendix Mate cable lengths over 36 inches, please call for a quote; cable lengths over 36 inches are priced at $3.03/ft.

  • 615-616 Series Transducers pic

    • Designed for heavy duty applications requiring high accuracy and durability
    • Extreme high pressure ranges from vacuum to 145,000 psi; Absolute ranges from 15 psia to 300 psia
    • Span and zero adjustments
    • Advanced diffused semi-conductor and sputtered thin film sensor for maximum stability
    • Excellent accuracy, shock resistance, and long term reliability
    • Rugged corrosion-resistant stainless steel construction
    • Available in a wide variety of electrical and process configurations
    • Compatible with NOSHOK 1900C and 2000 Series Smart System Indicators
    • Also available with our 1800 Series Attachable Loop Indicator
    • CE compliant to suppress RFI, EMI and ESD
    • Final calibration tests prior to shipment ensures 100% "out of the box" reliability

    psig = Gauge Pressure
    psia = Absolute Pressure
    Maximum Pressure = 6,000 psig


    Standard Unit Includes:

    • ±0.25% Full Scale Accuracy (BFSL)
    • 1/2” NPT Male Process Connection
    • Hirschmann electrical connection
    NOTE: Customer must select a desired accuracy (BFSL), output signal, process connection, and electrical connection at checkout.  Other options i.e. orifice threading and calibration certificates are also available at checkout.

    *Note: For Bendix Mate cable lengths over 36 inches, please call for a quote; cable lengths over 36 inches are priced at $3.03/ft.

  • 640 Series Transmitters pic

    • Designed for industrial and laboratory applications requiring high accuracy
      and repeatability
    • Temperature compensation system virtually eliminates temperature induced errors from 50°F to 104°F
    • Ranges include vacuum through 15,000 psi; absolute ranges from 15 psia
      to 300 psia
    • Standard output is USB (other outputs & electrical connections available)
    • Advanced diffused semi-conductor and sputtered thin film sensor provide maximum stability
    • Gauge or absolute pressure ranges
    • Outstanding accuracy and long term stability
    • High over range protection
    • Standard 1/2" NPT process connection
    • Corrosion resistant stainless steel construction
    • CE compliant to suppress RFI, EMI and ESD
    • Final calibration tests prior to shipment ensures 100% "out of the box" reliability
    • Communication software allows the capability of display, zero point adjustment and data logging of pressure and temperature through a PC
    psig = Gauge Pressure


    Standard Unit Includes:

    • ±0.05% Full Scale Accuracy (BFSL)
    • RS232, 8N1/9600 Baud Output Signal
    • 1/2” NPT Male Process Connection
    • RS232 Serial Interface Digital electrical connection

    NOTE: Customer must select a desired accuracy (BFSL), output signal, process connection, and electrical connection at checkout.  Other options i.e. orifice threading and calibration certificates are also available at checkout.

    *Note: For Bendix Mate cable lengths over 36 inches, please call for a quote; cable lengths over 36 inches are priced at $3.03/ft.

  • 660 Series Transducers pic

    • Combine high performance with compact size
    • Accuracy up to ±0.25% Full Scale (BFSL)
    • Standard ranges from 200 psi to 15,000 psi
    • Welded stainless steel pressure chamber for strength and durability
    • Sputtered thin film sensor provides stainless steel media compatibility and long term measurement stability
    • Designed to handle pressure spikes and process pulsation
    • Off-road capable due to high vibration and shock resistance
    • Variations in pressure connections, outputs and electrical connections are available and custom configurations are possible for volume applications
    • CE compliant to suppress RFI, EMI and ESD
    psig = Gauge Pressure


    Standard Unit Includes:
    • ¼” NPT Male process connection
    • M12 x 1 (4-pin) electrical connection
    NOTE: Customer must select a desired accuracy (BFSL), output signal, process connection, and electrical connection at checkout.  Other options i.e. orifice threading and calibration certificates are also available at checkout.

    *Note: For Bendix Mate cable lengths over 36 inches, please call for a quote; cable lengths over 36 inches are priced at $3.03/ft.

  • 755 Series Transducers Pic

    • Combines the reliability of diffused semi-conductor and sputtered thin film sensors with digital electronics for outstanding performance and value
    • Accuracy up to ±0.05% full scale (BFSL)
    • Up to 20:1 span turn down and -2.5% to 99% zero point adjustment for maximum flexibility
    • Built-in process temperature display & selectable process digital filtering
    • Welded 316 stainless steel pressure chamber
    • 32 point process linearization
    • Adjustable display for easy viewing
    • 12 different measurement units
    • User programming includes menus to allow the setting of user language, engineering units, zero and span calibration points and digital filtering to dampen pressure fluctuations
    • Stainless steel wetted parts are welded with no internal o-rings, gaskets or seals
    • CE compliant to suppress RFI, EMI and ESD
    psig = Gauge Pressure
    psia = Absolute Pressure


    Standard Unit Includes:
    • 1/2” NPT Male process connection
    • M20 x 1.5 Cable Gland with Internal Terminal Block electrical connection

    NOTE: Customer must select a desired accuracy (BFSL), output signal, process connection, and electrical connection at checkout.  Other options i.e. orifice threading and calibration certificates are also available at checkout.

    *Note: For Bendix Mate cable lengths over 36 inches, please call for a quote; cable lengths over 36 inches are priced at $3.03/ft.

  • 300 Series OEM Pressure Transducers pic

    • Rugged, compact transducer at an affordable price
    • Ideal for dynamic or static measurement in general industrial applications where 
      space is limited and durability is essential
    • Ranges from 0 psi to 15 psi through 0 psi to 10,000 psi
    • Standard absolute ranges from 15 psia to 200 psia
    • High quality stainless steel construction for compatibility with chemically 
      aggressive media
    • All welded design with no internal seals increases resistance to mechanical stress, 
      shock and vibration
    • Wide variety of electrical & mechanical connections and outputs available
    • Excellent EMC-protection compliant with EN 61326 – ideal for areas where RFI, 
      EMI, or ESD signals are present
    • RoHS compliant

    psig = Gauge Pressure
    psia = Absolute Pressure


    Standard Unit Includes:
    • ±0.5% Full Scale Accuracy (BFSL)
    • Hirschmann (DIN 43650A/EN 175301-803A) electrical connection

    NOTE: Customer must select a desired accuracy (BFSL), output signal, process connection, and electrical connection at checkout.  Other options i.e. orifice threading and calibration certificates are also available at checkout.

    *Note: For Bendix Mate cable lengths over 36 inches, please call for a quote; cable lengths over 36 inches are priced at $3.03/ft.

    *This product is ROHS Compliant  

  • 650 Series Transducers pic


    • Combine high performance with off-road vehicle reliability under severe process and
      environmental conditions
    • Standard ranges from 100 psi to 8,000 psi
    • Welded stainless steel pressure chamber prevents damage due to physical stress
    • Advanced diffused semi-conductor and sputtered thin film sensor provides stainless steel
      media capability and maximum stability
    • Designed to handle pressure spikes and process pulsation
    • Compact design
    • Wide variety of pressure ranges, connections, and outputs available
    • CE compliant to suppress RFI, EMI, and ESD

    psig = Gauge Pressure


    Standard Unit Includes:
    • ¼” NPT Male process connection
    • Packard Metripack 150 Series electrical connection

    NOTE: Customer must select a desired accuracy (BFSL), output signal, process connection, and electrical connection at checkout.  Other options i.e. orifice threading and calibration certificates are also available at checkout.

    *Note: For Bendix Mate cable lengths over 36 inches, please call for a quote; cable lengths over 36 inches are priced at $3.03/ft.

  • 619-620 Series pic

    • ATEX approved II 2G Ex d II C
    • For dynamic and static measurements
    • Excellent repeatability
    • High accuracy and long term stability
    • Increased accuracy of ±0.125% full scale (BFSL)
    • Excellent overload protection
    • Wide variety of pressure ranges
    • Corrosion-resistant stainless steel design
    • Welded pressure connection and measuring cell for exceptional shock and vibration resistance
    • CE compliant to suppress RFI, EMI, and ESD



    psig = Gauge Pressure
    psia = Absolute Pressure


    Standard Unit Includes:

    • ±0.25% Full Scale Accuracy (BFSL)
    • ½” NPT Male Process Connection
    • ½” NPT Male Conduit with 6 ft. integral cable electrical connection

     NOTE: Customer must select a desired accuracy (BFSL), output signal, process connection, and electrical connection at checkout.  Other options i.e. orifice threading and calibration certificates are also available at checkout.

    *Note: For Bendix Mate cable lengths over 36 inches, please call for a quote; cable lengths over 36 inches are priced at $3.03/ft.

  • 619-620 Series pic

    • ATEX approved II 2G Ex d II C
    • For dynamic and static measurements
    • Excellent repeatability
    • High accuracy and long term stability
    • Increased accuracy of ±0.125% full scale (BFSL)
    • Excellent overload protection
    • Wide variety of pressure ranges
    • Corrosion-resistant stainless steel design
    • Welded pressure connection and measuring cell for exceptional shock and vibration resistance
    • CE compliant to suppress RFI, EMI, and ESD


    psig = Gauge Pressure
    psia = Absolute Pressure


    Standard Unit Includes:

    • ±0.25% Full Scale Accuracy (BFSL)
    • ½” NPT Male Process Connection
    • ½” NPT Male Conduit with 6 ft. integral cable electrical connection

     NOTE: Customer must select a desired accuracy (BFSL), output signal, process connection, and electrical connection at checkout.  Other options i.e. orifice threading and calibration certificates are also available at checkout.

    *Note: For Bendix Mate cable lengths over 36 inches, please call for a quote; cable lengths over 36 inches are priced at $3.03/ft.

  • 621-622 Series Transmitters Pic


    • Designed for applications that require pressure measurement in hazardous locations
    • Accuracy to ±0.25% full scale (BFSL)
    • Wide variety of pressure ranges available
    • Advanced diffused semi-conductor and sputtered thin film sensor for maximum stability
    • Available with a standard threaded connection as well as a flush diaphragm configuration
    • Welded 316 stainless steel, and Elgiloy construction with no internal o-rings, gaskets or seals
    • 1/2" NPT conduit connection
    • Low power voltage outputs available
    • Incorporate significant levels of RFI, EMI, and ESD protection
    • CE compliant to suppress RFI, EMI, and ESD
    • Factory Mutual and Canadian Standards approved
    • NACE MR0175/ISO 15156 compliant
    • ANSI/ISA-12.27.01-2003 approved single seal

    psig = Gauge Pressure
    psia = Absolute Pressure


    Standard Unit Includes:
    • ±0.25% Full Scale Accuracy (BFSL)
    • ½” NPT Male Process Connection
    • ½” NPT Male Conduit with 6 ft. integral cable electrical connection

     NOTE: Customer must select a desired accuracy (BFSL), output signal, process connection, and electrical connection at checkout.  Other options i.e. orifice threading and calibration certificates are also available at checkout.

    *Note: For Bendix Mate cable lengths over 36 inches, please call for a quote; cable lengths over 36 inches are priced at $3.03/ft.

  • 621-622 Series Transmitters Pic


    • Designed for applications that require pressure measurement in hazardous locations
    • Accuracy to ±0.25% full scale (BFSL)
    • Wide variety of pressure ranges available
    • Advanced diffused semi-conductor and sputtered thin film sensor for maximum stability
    • Available with a standard threaded connection as well as a flush diaphragm configuration
    • Welded 316 stainless steel, and Elgiloy construction with no internal o-rings, gaskets or seals
    • 1/2" NPT conduit connection
    • Low power voltage outputs available
    • Incorporate significant levels of RFI, EMI, and ESD protection
    • CE compliant to suppress RFI, EMI, and ESD
    • Factory Mutual and Canadian Standards approved
    • NACE MR0175/ISO 15156 compliant
    • ANSI/ISA-12.27.01-2003 approved single seal

    psig = Gauge Pressure
    psia = Absolute Pressure


    Standard Unit Includes:
    • ±0.25% Full Scale Accuracy (BFSL)
    • ½” NPT Male Process Connection
    • ½” NPT Male Conduit with 6 ft. integral cable electrical connection

     NOTE: Customer must select a desired accuracy (BFSL), output signal, process connection, and electrical connection at checkout.  Other options i.e. orifice threading and calibration certificates are also available at checkout.

    *Note: For Bendix Mate cable lengths over 36 inches, please call for a quote; cable lengths over 36 inches are priced at $3.03/ft.

  • 623-624 Series Pic


    • Designed for applications that require pressure measurement in hazardous locations
    • Accuracy to ±0.25% full scale (BFSL)
    • Wide variety of pressure ranges available
    • Advanced diffused semi-conductor and sputtered thin film sensor for maximum stability
    • Available with a standard threaded connection as well as a flush diaphragm configuration
    • Welded 316 stainless steel with no internal o-rings, gaskets or seals - optional Hastelloy
      C4 on flush diaphragm model
    • 1/2" NPT conduit connection
    • Zener barriers are not required to meet non-incendive approval
    • CE compliant to suppress RFI, EMI, and ESD
    • NACE MR0175/ISO 15156 compliant
    • ANSI/ISA-12.27.01-2003 approved single seal
    • Factory Mutual & Canadian Standards Association Approved

     
    psig = Gauge Pressure
    psia = Absolute Pressure


    Standard Unit Includes:

    • ±0.25% Full Scale Accuracy (BFSL)
    • ½” NPT Male Process Connection
    • ½” NPT Male Conduit with 6 ft. integral cable electrical connection

     NOTE: Customer must select a desired accuracy (BFSL), output signal, process connection, and electrical connection at checkout.  Other options i.e. orifice threading and calibration certificates are also available at checkout.

    *Note: For Bendix Mate cable lengths over 36 inches, please call for a quote; cable lengths over 36 inches are priced at $3.03/ft.

  • 623-624 Series Pic


    • Designed for applications that require pressure measurement in hazardous locations
    • Accuracy to ±0.25% full scale (BFSL)
    • Wide variety of pressure ranges available
    • Advanced diffused semi-conductor and sputtered thin film sensor for maximum stability
    • Available with a standard threaded connection as well as a flush diaphragm configuration
    • Welded 316 stainless steel with no internal o-rings, gaskets or seals - optional Hastelloy
      C4 on flush diaphragm model
    • 1/2" NPT conduit connection
    • Zener barriers are not required to meet non-incendive approval
    • CE compliant to suppress RFI, EMI, and ESD
    • NACE MR0175/ISO 15156 compliant
    • ANSI/ISA-12.27.01-2003 approved single seal
    • Factory Mutual & Canadian Standards Association Approved

     
    psig = Gauge Pressure
    psia = Absolute Pressure


    Standard Unit Includes:

    • ±0.25% Full Scale Accuracy (BFSL)
    • ½” NPT Male Process Connection
    • ½” NPT Male Conduit with 6 ft. integral cable electrical connection


    NOTE: Customer must select a desired accuracy (BFSL), output signal, process connection, and electrical connection at checkout.  Other options i.e. orifice threading and calibration certificates are also available at checkout.

    *Note: For Bendix Mate cable lengths over 36 inches, please call for a quote; cable lengths over 36 inches are priced at $3.03/ft.

  • 625-626 Series Transmitters pic

    • Designed for applications that require pressure measurement in hazardous locations
    • Accuracy to ±0.125% Full Scale (BFSL)
    • Wide variety of pressure ranges available
    • Advanced diffused semi-conductor and sputtered thin film sensor for maximum stability
    • Available with a standard threaded connection as well as a flush diaphragm configuration
    • Welded 316 stainless steel with no internal o-rings, gaskets or seals - optional Hastelloy C4 on flush diaphragm model
    • Entity approved for use with all approved zener barriers where required
    • CE compliant to suppress RFI, EMI, and ESD
    • ANSI/ISA-12.27.01-2003 approved single seal
    • Factory Mutual & Canadian Standards Association approved

    psig = Gauge Pressure
    psia = Absolute Pressure


    Standard Unit Includes:
    • ±0.25% Full Scale Accuracy (BFSL)
    • 4 mA to 20 mA 2 Wire Output Signal
    • ½” NPT Male Process Connection
    • Hirschmann electrical connection (with mating connector)

    NOTE: Customer must select a desired accuracy (BFSL), output signal, process connection, and electrical connection at checkout.  Other options i.e. orifice threading and calibration certificates are also available at checkout.

    *Note: For Bendix Mate cable lengths over 36 inches, please call for a quote; cable lengths over 36 inches are priced at $3.03/ft.

  • 625-626 Series Transmitters pic

    • Designed for applications that require pressure measurement in hazardous locations
    • Accuracy to ±0.125% Full Scale (BFSL)
    • Wide variety of pressure ranges available
    • Advanced diffused semi-conductor and sputtered thin film sensor for maximum stability
    • Available with a standard threaded connection as well as a flush diaphragm configuration
    • Welded 316 stainless steel with no internal o-rings, gaskets or seals - optional Hastelloy C4 on flush diaphragm model
    • Entity approved for use with all approved zener barriers where required
    • CE compliant to suppress RFI, EMI, and ESD
    • ANSI/ISA-12.27.01-2003 approved single seal
    • Factory Mutual & Canadian Standards Association approved

    psig = Gauge Pressure
    psia = Absolute Pressure


    Standard Unit Includes:
    • ±0.25% Full Scale Accuracy (BFSL)
    • 4 mA to 20 mA 2 Wire Output Signal
    • ½” NPT Male Process Connection
    • Hirschmann electrical connection (with mating connector)

    NOTE: Customer must select a desired accuracy (BFSL), output signal, process connection, and electrical connection at checkout.  Other options i.e. orifice threading and calibration certificates are also available at checkout.

    *Note: For Bendix Mate cable lengths over 36 inches, please call for a quote; cable lengths over 36 inches are priced at $3.03/ft.

  • Noshok 11 Series Transmitters pic

    • Designed for heavy-duty sanitary applications where high accuracy, shock
      resistance and durability are required
    • Diffused semi-conductor or sputtered thin film sensor for maximum stability
    • Current or voltage output signals available to suit most applications
    • NEMA 4X, IP65 (IEC529)
    • 1-1/2" or 2" ASME-BPE Sanitary Clamp connections with integral cooling
      extension that allows for higher media temperatures
    • 316L stainless steel housing is welded to the ASME-BPE Sanitary Clamp process
      connection for greater strength and integrity
    • ASME-BPE Sanitary Clamp housing and diaphragm are constructed from
      316L stainless steel with wetted surfaces electropolished to Ra25 or better
    • Can be cleaned-in-place (CIP) or steamed-in-place (SIP)
    • CE compliant to suppress RFI, EMI, and ESD

    Standard Model Includes:

    • Bottom Mount Connection
    • 1-1/2” ASME-BPE Sanitary Clamp
    • White Oil Sanitary Seal Fill
    • 615 Series Transmitter
    • ±0.25% Full Scale Accuracy (BFSL)
    • Hirschmann (DIN 43650A) Electrical Connection

    NOTE: Customer must select a desired accuracy (BFSL), output signal, process connection, and electrical connection at checkout.  Other options i.e. orifice threading and calibration certificates are also available at checkout.

    *Note: For Bendix Mate cable lengths over 36 inches, please call for a quote; cable lengths over 36 inches are priced at $3.03/ft.


  • 21 Series Transmitter pic

    • High accuracy, heavy duty transmitter designed for high pressure sanitary homogenizer applications
    • Standard ranges from 1,000 psi to 15,000 psi
    • Span and zero adjustments
    • Sputtered thin film sensor for maximum stability, shock resistance and durability
    • Current or voltage output signals available to suit most applications
    • NEMA 4X, IP65 (IEC529)
    • 316L stainless steel housing is welded to the 1-1/8 inch flanged process connection for greater strength and integrity
    • 1-1/8" flanged housing and diaphragm are constructed from 316L stainless steel with wetted surfaces electropolished to Ra25 or better
    • Can be cleaned-in-place (CIP) or steamed-in-place (SIP)
    • CE compliant to suppress RFI, EMI, and ESD

    Standard Unit Includes:
    • Bottom Mount Connection
    • 1-1/8” Homogenizer Flange
    • White Oil Sanitary Seal Fill
    • 615 Series Transmitter
    • ±0.25% Full Scale Accuracy (BFSL)
    • Hirschmann (DIN 43650A) Electrical Connection

    NOTE: Customer must select a desired accuracy (BFSL), output signal, process connection, and electrical connection at checkout.  Other options i.e. orifice threading and calibration certificates are also available at checkout.

    *Note: For Bendix Mate cable lengths over 36 inches, please call for a quote; cable lengths over 36 inches are priced at $3.03/ft.

  • 800-810 Series Transmitters pic

    • 800 Series: stainless steel;
      810 Series:
      black anodized aluminum
    • Provides continuous pressure monitoring, allows programming of set points
      without applying pressure
    • Standard ranges from -14.5 psi to 9,999 psi
    • 3 switching output options available:
      • 2 switching outputs
      • 1 switching output and 1 analog output (4 mA to 20 mA or 0 Vdc to 10 Vdc)
      • 2 switching outputs and 1 analog output (4 mA to 20 mA)
    • Simple 2-key programming for set points, contact functions (N.O./N.C.), reset points,
      contact types (npn/pnp) and switching function (hysteresis/gate)
    • 330° rotatable display head
    • Integrated password protection
    • Four-digit LED display
    • Scalable analog output
    • Fast response time
    • CE compliant to suppress RFI, EMI, and ESD
    • Optional features: 330° rotatable pressure connection, minimum/maximum value memory,
      output dampening up to 2,000 ms, and switching time delay

    *Standard unit includes a 1/4" NPT Male process connection

    NOTE: Customer must select a desired accuracy (BFSL), output signal, process connection, and electrical connection at checkout.  Other options i.e. orifice threading and calibration certificates are also available at checkout.

    *Note: For Bendix Mate cable lengths over 36 inches, please call for a quote; cable lengths over 36 inches are priced at $3.03/ft.


  • 2200 Series Pressure Transducers pic

    *Please call to configure your pressure transducer and receive a quote.

    The 2200 series pressure transducer features stability and accuracy in a variety of enclosure options. The 2600 extends the packaging options via an all welded stainless steel back end for demanding submersible and industrial applications. The 2200 and the 2600 pressure transducers feature proven CVD sensing technology, an ASIC (amplified units), and modular packaging to provide a sensor line that can easily accommodate specials while not sacrificing high performance.

    22CS/26CS Series Intrinsically Safe Industrial Pressure Transmitters and 22FA/26FA Series CSA Intrinsically Safe Industrial Pressure Transmitters are now available.

    Features:

    • Millivolt, Voltage and Current Output
    • Gauge, Absolute, Vacuum and Compound Pressure
    • Submersible, General Purpose and Wash Down Enclosures 

    Applications:

    • Off-Highway Vehicles 
    • Natural Gas Equipment 
    • Semiconductor Processing 
    • Power Plants 
    • Refrigeration 
    • Robotics 
    • HVAC

  • 3100 Series Pressure Transducers pic

    *Please call to configure your pressure transducer and receive a quote.

    For OEMs that need consistent high levels of performance, reliability and stability the 3100 and 3200 series sputtered thin film pressure transducer unit offers an unbeatable price/performance ratio in a small package size. It features all-stainless steel wetted parts, a broad selection of electrical and pressure connections, and a wide choice of electrical outputs to allow stock configurations suitable for most applications without modification. At the heart of this series is a sputter element that also provides exceptional temperature specifications. The manufacturing process for the 3100 series includes the latest automated equipment, producing the most consistent and best price to performance sensor on the market today.

    Additionally, 3200 series transmitters feature thicker diaphragms and a pressure restrictor to withstand the rigors of cavitations or extreme pressure spikes, delivering years of reliable and stable performance in pulsating applications.

    The compact construction of this series makes it ideal for installation where space is at a premium. And it is fully RoHS compliant.

    Features:

    • 0-75 psi to 0-30,000 psi ranges (5 bar to 0-2,200 bar)
    • High Proof Pressures
    • Broad Choice of Outputs
    • RoHS Compliant

    Specifications:

    • Long Term Drift: 0.2% FS/YR (non-cumulative)
    • Accuracy: 0.25% FS
    • Thermal Error: 0.83% FS/100˚F (1.5% FS/100 ˚C)
    • Compensated Temperature: -40 ˚F to +257 ˚F (-40 ˚C to +125 ˚C)
    • Operating Temperature: -40 ˚F to +257 ˚F (-40 ˚C to +125 ˚C)
    • Zero Tolerance: 0.5% of span
    • Span Tolerance: 0.5% of span
    • Response Time: 1 ms
    • Fatigue Life: Designed for more than 100 M cycles
    • Wetted Parts: 17-4 PH Stainless Steel
    • Enclosure: IP67 (IP65 for electrical code G)
    • Vibration: 40G peak to peak sinusoidal, (Random Vibration: 20 to 1000 Hz @ approx. 40G peak per MIL-STD-810E)
    • Shock: Withstands free fall to IEC 68-2-32 procedure 1
    • EMC (Radiated Immunity): 100 V/m
    • Approvals: CE, conforms to European Pressure Directive, Fully RoHS compliant, UL recognized files #E219842 & E174228
    • Weight: 35 grams

     

  • 856 Series

    *Please call to configure your pressure transducer and receive a quote.

    The 856 series pressure transmitter is specifically designed for NEMA 4/IP65 service and features a die-cast aluminum enclosure. Their robust capacitive design is resistant to environmental effects, such as shock, vibration, temperature and EMI/RFI. A 17-4 PH stainless steel sensing element does not require isolation from a corrosive media. A ½" threaded conduit is provided for electrical termination and a removable cover provides easy access to the internal wiring terminal strip.


    Features:

    • 0-2 to 0-10,000 psi Pressure Ranges (0-690 bar)
    • Voltage or Current Output
    • NEMA 4/IP65 with Zero and Span Adjustments

    Applications:

    • Process Control
    • Chemical Processing
    • Agricultural Irrigation
    • Natural Gas Pipeline
    • Grain Processing
    • Industrial Pressure Monitoring

    Specifications:

    • Input Pressure Range: 0 to 10,000 psig (0 to 700 bar)
    • Input Fatigue Life:  > 1 million cycles
    • Supply Voltage (Vs): 9-30 VDC
    • Long Term Drift: 0.5% FS/year
    • Accuracy:
      • <25 psi: ±0.25% FS
      • ≥25 psi: ±0.13% FS
    • Thermal Error Zero:
      • <25 psi: ±0.02% FS/°F (±0.036% FS/°C)
      • ≥25 psi: ±0.01% FS/°F (±0.018% FS/°C)
    • Thermal Error Span: ±0.015% FS/°F (±0.027% FS/°C)
    • Compensated Temperatures: -4 °F to +176 °F (-20 °C to +80 °C)
    • Operating Temperatures: -40 °F to +260 °F (-40 °C to +125 °C)
    • Storage Temperatures: -40 °F to +260 °F (-40 °C to +125 °C)
    • Zero Tolerance: 0.5% of span (adjustable)
    • Span Tolerance: 1% of span (adjustable)
    • Wetted Parts: 17-4 PH Stainless Steel
    • Electrical Connection: Two ½” Internal Threaded Ports, Screw Terminal Strip
    • Enclosure: Die-Cast Aluminum, NEMA 4/IP65
    • Vibration: 20g (MIL STD 202, Method 204, Condition C)
    • Shock: 200g (MIL STD 202, Method 213B, Condition C)
    • Approvals: CE
    • Weight: 13.4 oz

  • T1000 Transducer pic
  • T1500 Transducers pic
  • Type 1500 Manifold