"Our job is helping you do your job"
800.544.2843Email 
  • Fluke-435-II

    More detailed power quality analysis capability, and a new Fluke-patented energy monetization function.

    The new 430 Series II Power Quality and Energy Analyzers offer the best in power quality analysis and introduce, for the first time ever, the ability  to monetarily quantify energy losses.  The new Fluke 434, 435 and 437 Series II  models help locate, predict, prevent, and trouble- shoot power quality problems in three-phase and single-phase power distribution systems. Additionally, the Fluke-patented energy loss  algorithm, Unified Power Measurement, measures and quantifies energy losses due to harmonics  and unbalance issues, allowing the user to pinpoint the origin of energy waste within a system.

     

  • Fluke 345 Power Quality Clamp Meters

    With a bright color display to analyze the harmonic spectrum, a low-pass filter to remove high frequency noise, and a high EMC immunity design, the Fluke 345 is ideal for measurements on switching loads such as variable speed drives, electronic lighting and UPS systems. Additionally, the Hall Effect measurement system makes measurement of dc current possible without the need to break the circuit, and the internal memory enables long-term logging for analysis of trends or intermittent problems.

    • AC/DC current: Clamp-on measurement of ac peak and dc current up to 2000 A without breaking the circuit.
    • Highest safety rating: 600 V CAT IV/1000 V CAT III rated for use at the service entrance.
    • Accurate measurement of parameters: Even with distorted waveforms present on electronic loads with low-pass filter.
    • Data logging: Identify intermittent faults by logging any power parameters for minutes or months, including harmonics.
    • Verify batteries: Direct measurement of dc ripple (%) for battery and dc systems.
    • Troubleshoot harmonics: Analyze and log harmonics digitally or graphically.
    • Inrush current: Capture and analysis from 3 seconds to 300 seconds.
    • Easy-to-use: Easily confirm instrument setup with large backlit color display of waveforms and trends.
    • Three-phase power: Built in capability for balanced loads.
    • View graphs and generate reports: With included Power Log software.
    • One-year warranty for accessories.

      Basic power quality measurements on the go with the Fluke 345
      A great introduction to power quality, this short application note teaches the basics of simple voltage, current waveform, harmonics, power, inrush, and logging measurements using the Fluke 345. Learn how to read waveforms and how and where to use them, and then learn about harmonics and how they distort voltage and current.

      Fluke 43B Power Quality Analyzer
      Power quality analysis plus a scope and a meter


      The Fluke 43B Power Quality Analyzer performs the measurements you need to maintain power systems, troubleshoot power problems, and diagnose equipment failures. The 43B has 20 storage locations and can store data as well as screens.
    • NiMH battery provides extended operating time of 6.5 hours.
    • Voltage, current, and power harmonics up to 51st.
    • Total harmonic distortion (THD).
    • Phase angle of individual harmonics.
    • Fluke View® software with enhanced analysis and documentation capabilities.
    • Continuously measure volts and amps cycle-by-cycle for up to 16 days.
    • Cursors give time and date of sags and swells.
    • Watts, power factor, displacement power factor, VA and VAR.
    • Voltage and current waveforms.
    • Calculates three-phase power on balanced loads from a single-phase measurement.
    • Catch up to 40 voltage transients and waveform distortions.
    • Three-year warranty for the PQ Analyzer.
    • One-year warranty for accessories.

  • Fluke 43B pic

    Fluke 43B Power Quality Analyzer
    Power quality analysis plus a scope and a meter


    The Fluke 43B Power Quality Analyzer performs the measurements you need to maintain power systems, troubleshoot power problems, and diagnose equipment failures. The 43B has 20 storage locations and can store data as well as screens.

    • NiMH battery provides extended operating time of 6.5 hours.
    • Voltage, current, and power harmonics up to 51st.
    • Total harmonic distortion (THD).
    • Phase angle of individual harmonics.
    • Fluke View® software with enhanced analysis and documentation capabilities.
    • Continuously measure volts and amps cycle-by-cycle for up to 16 days.
    • Cursors give time and date of sags and swells.
    • Watts, power factor, displacement power factor, VA and VAR.
    • Voltage and current waveforms.
    • Calculates three-phase power on balanced loads from a single-phase measurement.
    • Catch up to 40 voltage transients and waveform distortions.
    • Three-year warranty for the PQ Analyzer.
    • One-year warranty for accessories.

  • 8435

    The PowerPad® III Model 8435 has a memory capacity of 2GB for trend data storage: up to 50 captured snapshots, 210 captured transients, 1 inrush and 10,000 alarm events.  It comes equipped with four voltage and four current inputs, is CE Certified, and IP67 Rated (Cover Closed).

  • 2136.10

    The PowerPad® III Model 8333 is a three-phase power quality analyzer that is easy-to-use, compact and shock resistant. It enables technicians and engineers to measure and carry out diagnostics and power quality work on single- or three-phase networks. Three current and four voltage input terminals are provided are provided. It is IEC 61000-4-30 Class B and safety rated to 600V CAT IV.

    The Model 8333 has memory available for storing trend data, alarms, transients, and snapshot data.  The user can store up to 12 screen snapshots, up to 51 captured transients that contain four cycles for each active input, and 4,000 alarm events from up to 10 different parameters. Trend data can also be recorded for days, weeks or even months.

    IMPORTANT WARRANTY NOTE:
    By registering online within 30 days from the date of purchase, your warranty will be extended to 3 years


    Features:

    • Measurement of TRMS voltages up to 1000Vrms AC / 1200VDC for single or three phase networks
    • Measurement of TRMS currents up to 10kArms (sensor dependent)
    • Measures up to 5000ADC with the AC/DC Current Probe Model J93
    • Calculation of neutral current and voltage
    • Frequency measurement (40 to 70Hz systems)
    • Records and displays trend data as fast as once per second for one month up to 29 variables
    • Captures up to 51 transient occurrences on all V and A inputs
    • Measures harmonics (referenced to the fundamental or RMS value) for voltage, current or power up to the 50th harmonic
    • Recording, time stamping and characterization of disturbances (swells, sages and interruptions, exceedence of power and harmonic thresholds)
    • Measures energy VAh, VARh & Wh and reports quantities according to IEEE 1459 standards (P; Q1; D; N; S)
    • 65µs/sample transient recording
    • FREE DataView® software is included for configuring real-time display and report generation

    Applications:
    • Verification of power distribution circuits
    • In-plant troubleshooting of power distribution panels and individual machinery
    • Monitor pad mount transformers and phase unbalances
    • Determine harmonic problems originating from source or load
    • Determine transformer K-Factor
    • Energy metering (kVAh, VARh, kWh)

    Product Includes:
    • Three current probes
    • Four black 10 ft. voltage leads
    • Four black alligator clips
    • Twelve color-coded input ID markers
    • NiMH battery
    • 110/240V power adapter with US power cord
    • Carrying bag
    • Soft carrying pouch
    • USB stick supplied w/product user manual and DataView® software

  • 2136.30

    The PowerPad® III Model 8336 is a three-phase power quality analyzer that is easy-to-use, compact and shock resistant. It enables technicians and engineers to measure and carry out diagnostics and power quality work on one-, two- or three- phase networks. Five voltage and four current inputs are provided. It is IEC 61000-4-30 Class B and safety rated to 600V CAT IV.

    The Model 8336 has 2GB of memory available for storing trend data. Additional internal memory is used to let you store alarms, transients, and snapshot data.  The user can store up to 50 screen snapshots, up to 210 captured transients that contain four cycles for each active input, and 10,000 alarm events from up to 40 different parameters. Trend data can also be recorded for days, weeks or even months. Inrush current can also be captured and stored.

    IMPORTANT WARRANTY NOTE:
    By registering online within 30 days from the date of purchase, your warranty will be extended to 3 years.

    Features:

    • Measurement of TRMS voltages up to 1000Vrms AD/DC for two-, three-, four- or five-wire systems
    • Measurement of TRMS currents up to 10kArms (sensor dependent)
    • Measures up to 5000ADC with the AC/DC Current Probe Model J93
    • Frequency measurement (40 to 70Hz systems)
    • Records and displays trend data as fast as once per second for one month up to 41 variables
    • Captures up to 210 transient occurrences on all V and A inputs
    • Measures harmonics (referenced to the fundamental or RMS value) for voltage, current or power up to the 50th harmonic
    • Recording, time stamping and characterization of disturbance (swells, sages and interruptions, exceedence of power and harmonic thresholds)
    • 2GB SD Card for Trend Recording memory; Alarm, Snapshot, Transient and Inrush stored in internal flash memory
    • Measures energy VAh, VARh & Wh
    • 65µs/sample transient recording
    • FREE DataView® software is included for configuring real-time display and report generation
    Applications:
    • Verification of power distribution circuits
    • In-plant troubleshooting of power distribution panels and individual machinery
    • Monitor pad mount transformers and phase unbalances
    • Determine harmonic problems originating from source or load
    • Determine transformer K-Factor
    • Energy metering (kVAh, VARh, kWh)

    Product Includes:
    • Four current probes
    • Five black 10 ft. voltage leads
    • Five black alligator clips
    • Twelve color-coded input ID markers
    • USB cable
    •  NiMH battery
    • 110/240V power adapter with US power cord
    • Large classic tool bag
    • Soft carrying pouch
    • Quick Start user guide
    • USB stick supplied w/ product user manual and DataView® software

  • Accessories & Rep Parts for 8333 and 8336