- All CategoriesAll Categories
- Electrical InstrumentsElectrical Instruments
- Digital MultimetersDigital Multimeters
- Fluke Industrial MultimetersFluke Industrial Multimeters
- Item # FLUKE-87-5
Item # FLUKE-87-5, Industrial True-rms Multimeter with Temperature
FLUKE-87-5Industrial True-rms Multimeter with Temperature
List Price
-
$439.99Qty.
- Add To Cart
- Request Quote
Fluke Recommended Accessories
Diagnostic functions for maximum industrial productivity
The Fluke 87V has measurement functions, troubleshooting features, resolution and accuracy to solve more problems on motor drives, in-plant automation, power distribution and electro-mechanical equipment.
Unique function for accurate voltage and frequency measurements on adjustable speed motor drives and electrically noisy equipment (87V and 87V Ex). Large digit display with bright two level backlight makes the 87V significantly easier to read. Measure 20 A for up to 30 sec, 10 A continuously. Optional magnetic hanger for easy setup and viewing while freeing your hands for other tasks (TPAK). Expanded capacitance range to 10,000 µF. Built-in thermometer (87V).
Electrical safety
All inputs are protected to CAT III 1000 V and CAT IV 600 V. They can withstand impulses in excess of 8,000 V to help protect you from arc blast resulting from surges and spikes.
Fluke 87V/E2 Industrial Electrician's Combo Kit
Make industrial troubleshooting even more productive with accessories. 87V Industrial Multimeter C35 lightweight soft case to provide optimal protection and storage TL224 1.5 m silicone leads resist heat TP38 removable probes with 4 mm of exposed metal for use on industrial circuits AC220 retractable long reach alligator clips ToolPak™ meter hanging accessory to hold meter to steel surfaces 80BK-A K-type temperature probe
Available in intrinsically safe version as the Fluke 87V Ex.
Also available as 83V average responding multimeter
The Fluke 87V has measurement functions, troubleshooting features, resolution and accuracy to solve more problems on motor drives, in-plant automation, power distribution and electro-mechanical equipment.
Electrical safety
All inputs are protected to CAT III 1000 V and CAT IV 600 V. They can withstand impulses in excess of 8,000 V to help protect you from arc blast resulting from surges and spikes.
Fluke 87V/E2 Industrial Electrician's Combo Kit
Make industrial troubleshooting even more productive with accessories.
Available in intrinsically safe version as the Fluke 87V Ex.
Also available as 83V average responding multimeter
Calcert Gold
Calcert Gold is available for this item. You could purchase a plan to set up calibrations easily with us in the future life of this unit.
To learn more and purchase this plan: Click Here
Unit of Measure
Specifications
|
Features
|
Measuring Range and Accuracy
|
Basic Features
|
Measurements
|
Display
|
Data Storage and Exchange
|
Other Features
Specifications
Features |
N/A
|
Model |
N/A 87V |
Included Accessories |
N/A TL75 Test Leads, AC72 Alligator Clips, holster, 9 V battery (installed), 80BK-A Temperature Probe (87V only) CD-ROM (users manual and technical notes) and operator's guide. |
Applications |
N/A Electronic Industrial Process |
Manufacturer |
N/A Fluke® |
Delivery |
N/A Usually ships from stock within 1 business day |
Features
Selectable Filter for Accurate Voltage and Frequency Measurements on Motor Drives |
N/A 1 |
Built-in Thermometer Lets You Carry One Less Tool |
N/A 1 |
Large Display Digits and Two-level Bright White Backlight for Increased Visibility |
N/A 1 |
Peak Capture to Record Transients as Fast as 250 µs |
N/A 1 |
Measure Up to 1000 V AC and DC |
N/A 1 |
Measure Up to 10 A, 20 A for Up to 30 Seconds |
N/A 1 |
Auto and Manual Ranging for Maximum Flexibility |
N/A 1 |
Min/Max and Average Recording to Capture Variations Automatically |
N/A 1 |
Relative Mode to Remove Test Lead Resistance From Low Ohms Measurements |
N/A 1 |
Access Door for Fast Battery Changes Without Breaking the Calibration Seal |
N/A 1 |
Measuring Range and Accuracy
AC Current Range and Resolution |
N/A 10.00 A 6.000 A 60.00 µA 600.0 µA 600.0 mA 6000 µA |
Resistance Range and Resolution |
N/A 50.00 MΩ 6.000 kΩ 6.000 MΩ 60.00 kΩ 600.0 Ω 600.0 kΩ |
Best Accuracy |
N/A 80BK Temperature Probe: 2.2 °C or 2 % AC Current: 1.0 %(true-rms) AC Voltage: 0.7 %(true-rms) Capacitance: 1.0% DC Current: 0.2 % DC Voltage: 0.05 % Frequency: 0.005 % Resistance: 0.2 % Temperature (excluding probe): 1.0 % |
Battery Life |
N/A 400 hours typical with backlight off. |
Length |
N/A 7.9 in201 mm |
Width |
N/A 3.8 in98 mm |
Depth |
N/A 2 in52 mm |
Weight |
N/A 355 g22 oz |
Basic Features
True RMS Readings |
N/A AC |
Basic DC Accuracy |
N/A 0.05 % |
Wide Bandwidth |
N/A 20 kHz |
Auto/Manual Ranging |
N/A 1 |
Digits |
N/A 4-1/2 |
Counts |
N/A 20000 |
Measurements
Current AC/DC |
N/A 10 A |
Resistance |
N/A 50 MΩ |
Frequency |
N/A 200 kHz |
Capacitance |
N/A 10 mF |
Temperature |
N/A +1090 ºC |
Conductance |
N/A 50 ns |
Duty Cycle/Pulse Width |
N/A 1 |
Motor Drive Measurement/Low Pass Filter |
N/A 1 |
Low Ohms (50 Ω) |
N/A 0 |
Display
Dual Display |
N/A 0 |
Analog Bargraph |
N/A 1 |
Backlight |
N/A 1 |
Min/Max Recording |
N/A 1 |
Min/Max Recording/with Time Stamp |
N/A 0 |
Fast Min/Max |
N/A 250 µs |
Relative Reference |
N/A 1 |
PC Interface |
N/A 0 |
Data Storage and Exchange
Automatic Selection, LoZ |
N/A 0 |
LoZ |
N/A 0 |
VoltAlert, Non-Contact AC Voltage Detector |
N/A 0 |
Real-Time Clock |
N/A 0 |
Overmolded Case, Integrated Holster |
N/A 0 |
Removable Holster |
N/A 1 |
Toolpak Magnetic Hanger Compatibility |
N/A 1 |
Closed Case Calibration |
N/A 1 |
Separate Battery Door |
N/A 1 |
Completely Sealed/watertight |
N/A 0 |
Automatic Power Off |
N/A 1 |
Low Battery Indication |
N/A 1 |